A-61003 September 1993
FC-13
Function Code Name/
Code Description Additional Input
F66 Partial Bar Code Reading • Enter the number zero (0) to turn partial
On/Off bar code reading OFF; or
Allows you to turn partial enter the number one (1) to turn partial
bar code reading on or off. bar code reading ON.
• Press the Enter key.
F70 Length Checking On/Off • Enter the number one (1) to turn length
Allows you to turn length checking ON; or
checking on or off. enter the number zero (0) to turn length
checking OFF.
• Press the Enter key.
F71 Omit Length Checking • Enter the number one (1) to omit length
On Next Document Only checking on the next document only; or
Allows you to omit length enter the number zero (0) to perform length
checking on the next document checking on the next document.
only. • Press the Enter key.
F72 Skew Detection • Enter the number one (1) to turn skew
Allows you to turn skew detection ON; or
detection on or off. enter the number zero (0) to turn skew
detection OFF.
• Press the Enter key.
F73 Latched Scanning Flag • Enter the number one (1) to turn the latched
Allows you to set a flag which scanning flag ON; or
alerts the host system that the enter the number zero (0) to turn the latched
document, and those which scanning flag OFF.
follow, are of special interest. • Press the Enter key.
The flag will remain activated
for every document until
it is turned off.
F74 Momentary Scanning Flag • Enter the number one (1) to turn the
Allows you to set a flag which momentary scanning flag ON.
alerts the host system that the • Press the Enter key.
next document only is of
special interest.